Military Generator G20M – 20 kVA
G20M / 20 KVA FIELD POWER Military Generator G20M – 20 kVA
The Military Generator G20M – 20 kVA is a deployable power generation solution developed for high-demand military applications where multiple electrical systems require dependable energy beyond stable grid infrastructure. Its rugged field-oriented construction supports communications, medical equipment, radar installations, emergency response systems and other power-intensive mission equipment in demanding operational environments.
Deployable 20 kVA military generator platform for high-capacity field power, power-intensive mission equipment and sustained operational use.
High-Capacity Power Generation for Complex Field Missions
The Military Generator G20M – 20 kVA is intended for operational environments where multiple high-consumption electrical systems must remain available when fixed infrastructure is unavailable, unstable or disrupted. Its rugged construction combines higher power capacity with field deployment capability for demanding military and emergency-response roles.
Available configurations may vary by fuel type, acoustic characteristics, portability level, physical dimensions, weight and installation requirements. Gasoline and diesel operation are identified as configuration-dependent options, allowing individual configurations to address different mission profiles.
Sustained Electrical Support for Power-Intensive Equipment
The G20M is specified with 20 kVA output power and 15 kVA continuous power. The supplied technical data additionally lists 380 VAC output voltage and a maximum current of 22 A.
The generator can automatically activate when the main electrical supply to equipment shelters is interrupted. A military-grade AGM battery with a minimum capacity of 40 Ah supports startup, including ambient temperatures down to −32°C when supported by a pre-heater.
Power15
kVA
Field Endurance with Integrated Operating Protection
The supplied product information describes automatic shutdown functions for overload, overheating, low fuel level and abnormal operating conditions. The technical specifications identify a water-cooled system and a sound level of 75 dB at 7 m.
At full load, the generator is stated to operate for a minimum of eight hours from its internal fuel tank without refueling. Electrical connectors are identified according to MIL-DTL-38999 and/or VG95234. The control board is separately stated to have IP67 protection, while the overall generator protection level in the technical table is IP23.
G20M Field Power Features
20 kVA Output Power
The supplied technical data specifies 20 kVA output power for demanding deployed electrical applications.
15 kVA Continuous Power
Continuous power is listed as 15 kVA for sustained support of operational electrical loads.
Automatic Power-Loss Start
The generator can activate automatically following interruption of the primary supply to supported equipment shelters.
Eight-Hour Full-Load Endurance
The supplied information states at least eight hours of full-load operation from the internal fuel tank without refueling.
Automatic Protection Functions
Shutdown protection is described for overload, overheating, low fuel level and other abnormal operating conditions.
IP67 Control Board Protection
The control board is separately identified with IP67 protection against dust and water ingress.
Mission-Oriented G20M Configurations
Fuel Configuration
- Options
- Gasoline or diesel depending on configuration.
- Selection
- Defined according to mission and operating requirements.
- Purpose
- Adaptation to different deployed power scenarios.
Deployment Configuration
- Immediate Use
- Selected variants are intended for operation without installation.
- Assembly
- Other variants may require assembly before deployment.
- Variation
- Portability, dimensions, weight and installation requirements may differ.
Operational Configuration
- Noise
- Certain configurations support reduced-noise operation.
- Control
- A simplified control panel supports efficient field use.
- Cooling
- Water-cooled system specified in the technical data.
Operational Applications
Environmental, Reliability and Electrical References
The supplied product information lists military standards addressing environmental durability, reliability, electromagnetic compatibility and electrical power requirements. Military electrical connector references are separately stated as MIL-DTL-38999 and/or VG95234.
Frequently Asked Questions
01What continuous power value is specified for the G20M?
The supplied technical data lists 15 kVA continuous power.
02What output voltage is listed for the G20M?
The technical table specifies an output voltage of 380 VAC.
03What is the listed system weight of the G20M?
The supplied technical data specifies a system weight of 900 kg ±5.
04What fuel consumption value is provided for the generator?
The supplied specifications list fuel consumption as 8.6 L/H.
05What dimensions are provided for the G20M?
The supplied dimensions are 1484 × 1318 × 791 mm ±5.
Technical Data
Need More Information About the Military Generator G20M – 20 kVA?
Contact our team for G20M configuration, deployment and military field power requirements.