Military Generator 25 kVA – G25M

Portable Military Power Military Generator 25 kVA G25M G25M / 25 KVA FIELD POWER

Military Generator 25 kVA – G25M

The Military Generator 25 kVA – G25M is a mobile field power unit developed for military applications requiring dependable electrical supply when fixed grid infrastructure is unavailable or unreliable. Its diesel-powered configuration combines 25 kVA output capacity with rapid deployment, sustained field operation and support for mission-critical electrical systems.

Output Power25 kVA
Continuous Power20 kVA
Output Voltage220 VAC
Fuel TypeDiesel

Mobile 25 kVA military generator platform for continuous field power, equipment shelters and mission-support systems.

Mobile Electrical Power for Field-Deployed Systems

The Military Generator 25 kVA – G25M provides an independent electrical source for military equipment operating beyond dependable grid infrastructure. Its mobile structure supports rapid field deployment while maintaining the power characteristics required by communications, medical equipment, radar systems, equipment shelters and other operational loads.

The G25M uses a diesel engine and supports F54, F34 and F65 fuel types. The supplied product information identifies 220 VAC / 50 Hz single-phase electrical output, while the technical data lists 25 kVA output power and 20 kVA continuous power.

01 / FIELD DEPLOYMENT

Independent Power Support for Operational Infrastructure

The G25M is intended for field operations requiring continuous electrical availability across mobile military units, ground and air platforms, equipment shelters, emergency-response systems and other mission-support infrastructure.

Automatic activation is supported when mains electricity supplied to an equipment shelter is interrupted. The generator uses a military-grade AGM battery with a minimum capacity of 40 Ah, with the supplied information specifying at least three cold starts at −32°C when supported by a pre-heater.

Continuous
Power
20
kVA

Fuel Flexibility and Extended Field Endurance

The diesel-powered G25M supports F54, F34 and F65 fuels. At full load, the generator is stated to operate for a minimum of eight hours from its internal fuel tank without refueling.

Electrical connectors are identified according to MIL-DTL-38999 and/or VG95234. The control board is separately specified with IP67 enclosure protection, while the generator technical table lists the overall protection level as IP23.

Operational Characteristics

G25M Field Power Features

01

25 kVA Output Power

The technical data specifies 25 kVA output power for deployed military electrical systems.

02

20 kVA Continuous Power

Continuous power is listed as 20 kVA for sustained operational electrical loads.

03

Multi-Fuel Diesel Operation

The diesel engine is stated to support F54, F34 and F65 fuel types.

04

Eight-Hour Full-Load Endurance

The internal fuel tank supports at least eight hours of operation at full load without refueling.

05

Automatic Backup Activation

The generator can activate automatically following interruption of mains electricity to supported equipment shelters.

06

IP67 Control Board

The control board enclosure is specified to IP67 for protection against environmental exposure.

System Architecture

G25M Power and Deployment Configuration

SYSTEM / 01

Fuel System

Engine Fuel
Diesel.
Supported Fuels
F54, F34 and F65.
Endurance
Minimum eight hours at full load from the internal tank.
SYSTEM / 02

Electrical Output

Output Power
25 kVA.
Continuous Power
20 kVA.
Supply
220 VAC / 50 Hz single-phase.
SYSTEM / 03

Cold-Start & Protection

Battery
Military-grade AGM, minimum 40 Ah.
Cold Start
At least three starts at −32°C with pre-heater support.
Control Board
IP67 enclosure protection.
Deployment Areas

Operational Applications

Mobile Military Units
Ground and Air Platforms
Equipment Shelters
Communication Infrastructure
Medical and Radar Systems
Emergency Response Operations
Military Standards & Testing

Environmental, Reliability and Electrical References

The supplied product information lists military standards covering environmental durability, reliability, electromagnetic compatibility and electrical power requirements. Connector specifications separately reference MIL-DTL-38999 and/or VG95234.

MIL-STD-810
MIL-HDBK-217F
MIL-STD-461F
MIL-STD-704F
FAQ / PRODUCT

Frequently Asked Questions

01What continuous power is specified for the G25M?

The technical data lists 20 kVA continuous power.

02What is the maximum current value listed for the generator?

The supplied technical table specifies a maximum current of 16 A.

03What is the specified system weight of the G25M?

The listed system weight is 860 kg ±5.

04What fuel consumption value is provided for the G25M?

The technical specifications list fuel consumption as 6.1 L/H.

05What dimensions are specified for the G25M?

The supplied dimensions are 1907 × 664 × 1406 mm ±5.

Military Generator 25 kVA – G25M Specifications

Technical Data

Output Power25 kVA
Output Voltage220 VAC
Continuous Power20 kVA
Maximum Ampere16 A
Operating Temperature-32 / +49 °C
Storage Temperature-40°C ~ +60°C
Integrated Cooling SystemWater Cooled
Sound Level75 dB @ 7 m
Maximum Operating Elevation3000 m
Protection LevelIP23
System Weight860 kg ±5
Fuel Consumption6.1 L/H
Connection TypeRS422, TCP
Dimensions1907 × 664 × 1406 mm ±5
Fire Bulgaria / Product Support

Need More Information About the Military Generator 25 kVA – G25M?

Contact our team for G25M fuel, deployment and military field power requirements.

Request Information