Military Generator 28 kVA – G28M

Portable Military Power Military Generator 28 kVA G28M G28M / 28 KVA FIELD POWER

Military Generator 28 kVA – G28M

The Military Generator 28 kVA – G28M is a mobile field power system developed for military applications requiring dependable electrical supply beyond stable grid infrastructure. Its portable and rugged architecture supports rapid deployment while providing sustained power for communications, medical equipment, radar systems, emergency-support units and other mission-critical electrical loads.

Output Power28 kVA
Continuous Power22.5 kVA
Output Voltage380 VAC
Maximum Ampere33 A

Mobile 28 kVA military generator platform for independent field power, equipment shelters and mission-critical support systems.

Higher-Capacity Mobile Power for Field Operations

The Military Generator 28 kVA – G28M provides an independent electrical source for military systems operating away from dependable grid infrastructure. Its portable structure supports field deployment and relocation while supplying power to communications, medical equipment, radar systems, emergency-support equipment and other operational loads.

The supplied technical table specifies 28 kVA output power, 22.5 kVA continuous power, 380 VAC output voltage and a maximum current of 33 A. These technical-table values are used as the authoritative electrical specifications for this product.

01 / FIELD POWER

Deployable Electrical Support for Mission-Critical Systems

The G28M is intended for field locations where independent power generation must support mobile military units, ground and air platforms, communications, medical devices, radar equipment and emergency-response systems.

The generator uses a diesel engine and supports F54, F34 and F65 fuel types. A military-grade AGM battery with a minimum capacity of 40 Ah supports at least three generator activations at −32°C when used with a pre-heater.

Continuous
Power
22.5
kVA

Extended Endurance with Protected Field Control

The generator can automatically activate if mains electricity supplied to an equipment shelter is interrupted. At full load, the supplied information states a minimum operating duration of eight hours from the internal fuel tank without refueling.

The control board is separately specified with IP67 protection, while the generator technical table lists an overall protection level of IP23. Electrical connectors are identified according to MIL-DTL-38999 and/or VG95234.

Operational Characteristics

G28M Field Power Features

01

28 kVA Output Power

The supplied technical data specifies 28 kVA output power for deployed military electrical systems.

02

22.5 kVA Continuous Power

Continuous power is listed as 22.5 kVA for sustained operational electrical loads.

03

Multi-Fuel Diesel Operation

The diesel engine is stated to support F54, F34 and F65 fuel types.

04

Eight-Hour Full-Load Endurance

The internal fuel tank supports at least eight hours of full-load operation without refueling.

05

Automatic Backup Activation

The generator can activate automatically following interruption of mains electricity to supported equipment shelters.

06

IP67 Control Board

The control board is separately specified with IP67 protection against dust and water ingress.

System Architecture

G28M Power and Deployment Configuration

SYSTEM / 01

Electrical Configuration

Output Power
28 kVA.
Continuous Power
22.5 kVA.
Output Voltage
380 VAC according to the technical table.
SYSTEM / 02

Fuel & Endurance

Engine
Diesel.
Supported Fuels
F54, F34 and F65.
Endurance
Minimum eight hours at full load from the internal tank.
SYSTEM / 03

Cold-Start & Protection

Battery
Military-grade AGM, minimum 40 Ah.
Cold Start
At least three activations at −32°C with pre-heater support.
Control Board
IP67 protection.
Deployment Areas

Operational Applications

Mobile Military Units
Ground and Air Platforms
Communication Systems
Medical Equipment
Radar Systems
Emergency Response Operations
Military Standards & Testing

Environmental, Reliability and Electrical References

The supplied product information lists military standards covering environmental durability, reliability, electromagnetic compatibility and electrical power requirements. Connector specifications separately reference MIL-DTL-38999 and/or VG95234.

MIL-STD-810
MIL-HDBK-217F
MIL-STD-461F
MIL-STD-704F
FAQ / PRODUCT

Frequently Asked Questions

01What continuous power value is specified for the G28M?

The supplied technical table lists 22.5 kVA continuous power.

02What output voltage is listed in the G28M technical data?

The authoritative technical table specifies 380 VAC.

03What maximum current is specified for the generator?

The supplied technical data lists a maximum current of 33 A.

04What fuel consumption value is provided for the G28M?

The technical specifications list fuel consumption as 8.6 L/H.

05What dimensions are specified for the G28M?

The supplied dimensions are 1198 × 800 × 1620 mm ±5.

Military Generator 28 kVA – G28M Specifications

Technical Data

Output Power28 kVA
Output Voltage380 VAC
Continuous Power22.5 kVA
Maximum Ampere33 A
Operating Temperature-32 / +49 °C
Storage Temperature-40°C ~ +60°C
Integrated Cooling SystemWater Cooled
Sound Level75 dB @ 7 m
Maximum Operating Elevation3000 m
Protection LevelIP23
System Weight1000 kg ±5
Fuel Consumption8.6 L/H
Connection TypeRS422, TCP
Dimensions1198 × 800 × 1620 mm ±5
Fire Bulgaria / Product Support

Need More Information About the Military Generator 28 kVA – G28M?

Contact our team for G28M fuel, deployment and military field power requirements.

Request Information