Military Generator 60 kW – G60M
G60M / 60 KW MILITARY POWER Military Generator 60 kW – G60M
The Military Generator 60 kW – G60M is a high-capacity field power platform delivering 60 kW at 380 V AC for demanding military applications. Its control architecture supports automatic starting during mains failure, synchronization, load sharing, standalone operation, mains-parallel operation and multi-generator parallel operation for flexible mission power management.
60 kW military generator with automatic mains-failure start, synchronization, load sharing and parallel power-management capabilities.
High-Capacity Power with Parallel Operating Capability
The Military Generator 60 kW – G60M delivers 60 kW of electrical power at 380 V AC. Its generator control unit supports standalone operation, parallel operation with the mains and parallel operation of multiple generators, allowing the power architecture to adapt to different operational requirements.
The system starts automatically if the mains supply to the equipment shelter fails. The supplied operating limits specify a temperature range of −32°C to +50°C and operation at altitudes up to 3,000 m above sea level.
Turbocharged Diesel Power Generation Architecture
The G60M uses a Perkins horizontal diesel engine with turbocharging and water cooling. The supplied technical information lists mechanical engine power of 75–117.5 kWm and an operating speed of 1500 RPM, with an electric starter motor used for engine starting.
The brushless alternator incorporates self-regulating voltage, voltage regulation accuracy of ≤ ±2%, Class H insulation and an IP23 protection rating. Maximum alternator unbalanced load is specified as 30%.
Power60
kW
Automatic Synchronization and Load Management
The generator control unit supports mains-parallel and multi-generator parallel operation together with automatic synchronization, load sharing and power management. Control functions include dynamic reserve power management, peak-load management, automatic load shedding, event-based history logs and user-defined protection and configuration functions.
Steady-state voltage fluctuation and steady-state frequency fluctuation are each specified as ≤ 2%. Earth leakage protection is listed at 300 mA.
G60M Power Management Features
Automatic Mains-Failure Start
The G60M starts automatically if the mains supply to the supported equipment shelter is interrupted.
Synchronization & Load Sharing
The control unit supports automatic synchronization and load sharing for coordinated power operation.
Parallel Power Operation
Standalone, mains-parallel and multiple-generator parallel operating modes are supported.
J1939 Device Communication
The control unit communicates with the engine ECU, AVR and other J1939 devices.
Remote Monitoring
Remote monitoring and control are supported, with remote connection available through AirGate 2.0.
5-Inch Color Display
A 5-inch color display provides the local generator control interface.
Control, Communication and Runtime
Communication
- Protocols
- Modbus RTU/TCP, SNMP and J1939.
- Interfaces
- RS485 and Ethernet.
- Remote Access
- Remote monitoring and control with AirGate 2.0 connection support.
Starting & Battery
- Battery
- Military-grade AGM, minimum 120 Ah.
- Cold Start
- At least three starts at −32°C with preheater support.
- Automatic Start
- Activated following mains-supply failure to the equipment shelter.
Fuel Runtime
- Integral Tank
- 10 hours of runtime.
- Vehicle Replenishment
- At least 24 hours at full load with fuel replenishment from the vehicle fuel tank.
- Fuel Consumption
- 10 L as listed in the supplied technical table.
Military Power Applications
Environmental and EMI/RFI Test References
The supplied information lists MIL-STD-810G environmental testing covering solar radiation, high and low temperature operation and storage, humidity, rain spray, vibration, shock, dust and sand, salt fog, thermal shock, icing and freezing rain. MIL-STD-461F EMI/RFI characteristics include CE102, RE102, CS114, CS115, CS116 and RS103. Connector and power-cable references are MIL-DTL-38999 / VG95234 and MIL-DTL-27500 respectively.
Frequently Asked Questions
01What mechanical power range is specified for the G60M engine?
The supplied technical data lists engine mechanical power of 75–117.5 kWm.
02Which communication interfaces are listed for the generator?
The technical table specifies RS485 and Ethernet.
03What protection ratings are specified for the alternator and control panel?
The alternator is specified as IP23, while the control panel is separately specified as IP65.
04What system weight is listed for the G60M?
The supplied technical data lists a system weight of 2,000 kg (±10 kg).
05What are the specified dimensions of the G60M?
The supplied dimensions are 2390 × 1024 × 1865 mm (±15 mm) in L × W × H order.
Technical Data
Need More Information About the Military Generator 60 kW – G60M?
Contact our team for G60M synchronization, parallel operation, control and military field power requirements.