The Auxiliary Power Unit – A20K is an onboard power generation system developed to maintain mission-critical military vehicle systems when the main engine is switched off or unavailable. Integrated into the vehicle architecture, it supports electrical, pneumatic and hydraulic subsystems, onboard climate control and sustained operational readiness under demanding mission conditions.

Output Voltage28 VDC
Continuous Power24 kVA
Maximum Ampere220 A
Noise Level85 dB @ 7 m

Integrated auxiliary power platform for main-engine-off operation, co-generation, silent-mode support and mission-system continuity.

Independent Onboard Power for Mission-Critical Systems

The Auxiliary Power Unit – A20K provides power to vehicle subsystems without requiring continuous operation of the main engine. It supports pre-mission activities such as weapon and system testing, vehicle diagnostics and main-engine cooling, while helping selected systems remain operational when the primary engine is damaged or unavailable.

The system also provides autonomous onboard power for operations where fixed external power infrastructure is not available.

01 / PLATFORM INTEGRATION

Integration Across Ground, Stationary and Airborne Platforms

The A20K is intended for tracked and wheeled armored vehicles, stationary systems and airborne platforms. Supplied examples include main battle tanks, self-propelled artillery systems, armored and infantry fighting vehicles, armored personnel carriers, MRAP vehicles, tactical and support vehicles, rocket systems, shelters, tents, helicopters and aircraft.

Depending on platform design and mission requirements, the unit can be installed within a sound-insulated internal compartment or mounted externally to address thermal-management and acoustic requirements.

Continuous
Power
24
kVA

Power Architecture for High-Demand Mission Equipment

The broader APU architecture described in the supplied information supports configurations from 2 kW to 20 kW and provides 24/28 VDC as well as higher AC and DC voltage options. The A20K technical table itself specifies 24 kVA continuous power.

The system is integrated with vehicle fuel and control architecture and draws fuel directly from the vehicle fuel tank without requiring a separate fuel tank or battery. Depending on application requirements, air-cooled or liquid-cooled diesel architectures may be configured; the A20K technical table specifically lists Water Cooled.

Operational Capabilities

A20K Auxiliary Power Features

01

Main-Engine-Off Power

The A20K supports selected vehicle systems without requiring the main engine to remain operational.

02

Autonomous Onboard Supply

The system supports missions where fixed external power infrastructure is unavailable.

03

Co-Generation Capability

The APU can monitor onboard demand and supplement the vehicle's main generator when additional power is required.

04

Vehicle Fuel Integration

Fuel is drawn directly from the vehicle fuel tank without requiring a separate APU fuel reservoir.

05

Automatic & Manual Start

The electronic control system supports automatic and manual starting for different mission profiles.

06

Real-Time Monitoring

The digital control interface provides operational parameters and fault-condition information to the operator.

System Architecture

Electrical, Cooling and Control Configuration

SYSTEM / 01

Electrical Output

Output Voltage
28 VDC.
Continuous Power
24 kVA.
Maximum Ampere
220 A.
SYSTEM / 02

Vehicle Integration

Fuel Source
Vehicle fuel tank.
Dedicated Tank / Battery
Not required according to the supplied product information.
Cooling
Water Cooled according to the A20K technical table.
SYSTEM / 03

Control & Monitoring

Electronic Control Unit
IP67-rated ECU with digital display.
Start Modes
Automatic and manual.
Displayed Data
Temperature, fuel level, pressure, DC current, battery voltage and fault conditions.
Deployment Areas

Operational Applications

Main Battle Tanks
Self-Propelled Artillery & Rocket Systems
Armored Fighting Vehicles & APCs
MRAP & Tactical Vehicles
Shelters & Stationary Systems
Helicopters & Aircraft
02 / FUNCTIONAL ROLE

Auxiliary Support for Vehicle Electronics and Mission Equipment

The A20K can supply onboard electronics, hydraulic and pneumatic systems, climate-control units, weapon systems, communication equipment, fire suppression systems, power distribution units and KBRN systems independently of continuous main-engine operation.

Its co-generation mode enables the APU to operate alongside the primary generator, continuously monitor electrical demand and compensate for power deficits when additional mission equipment increases onboard loads.

Military Test Standards

Environmental, EMC, Electrical and Reliability References

The supplied product information states that the A20K is designed and tested in accordance with the following military standards for electromagnetic compatibility, environmental performance, electrical power and reliability considerations.

MIL-STD-461
MIL-STD-810
MIL-STD-704
MIL-HDBK-217
FAQ / PRODUCT

Frequently Asked Questions

01What continuous power and output voltage are specified for the A20K?

The technical table specifies 24 kVA continuous power and 28 VDC output voltage.

02What maximum current is listed for the A20K?

The supplied technical data lists a maximum current of 220 A.

03What temperature ranges are specified for operation and storage?

The operating range is -32°C ~ +55°C, while the storage range is -40°C ~ +60°C.

04What noise level and system weight are specified?

The technical table lists 85 dB @ 7 m and a system weight of 350 kg ±5.

05What dimensions and fuel consumption are listed for the A20K?

The supplied data specifies 3190 × 1190 × 875 mm ±5 dimensions and 7.8 L/H fuel consumption.

Auxiliary Power Unit – A20K Specifications

Technical Data

Output Voltage28 VDC
Continuous Power24 kVA
Maximum Ampere220 A
Operating Temperature-32°C ~ +55°C
Storage Temperature-40°C ~ +60°C
Integrated Cooling SystemWater Cooled
Noise Level85 dB @ 7 m
System Weight350 kg ±5
Fuel Consumption7.8 L/H
Dimensions3190 × 1190 × 875 mm ±5
Fire Bulgaria / Product Support