Smoke Launcher Control Unit DC-4
UMAY / DC-4 CONTROL UNIT
Smoke Launcher Control Unit DC-4
Smoke Launcher Control Unit UMAY DC-4 is a compact control unit developed to manage smoke grenade launcher systems and laser warning integration on military and law enforcement vehicles. Designed for flexible deployment, the unit enables controlled smoke grenade launching to support vehicle protection and tactical concealment requirements.
Compact command interface with configurable ammunition channels, directional launcher control and laser warning integration capability.
Compact Control for Vehicle Self-Protection and Tactical Obscuration
UMAY DC-4 is designed to control smoke grenade launchers used for vehicle self-protection and situational obscuration. The unit supports both automatic and manual firing modes, allowing operators to respond effectively to threats while coordinating with laser warning systems when integrated.
Deployment Areas
The control unit is deployed on military vehicles, law enforcement platforms, anti-riot vehicles and tactical security vehicles equipped with smoke grenade launcher systems.
It is suitable for applications requiring compact control architecture and directional smoke deployment capability.
Design UMAY
DC-4
Configuration and Structural Design
UMAY DC-4 can control multiple smoke grenades, with the number of ammunition channels configurable according to vehicle layout and customer requirements. Smoke grenades positioned on left, right, front and rear sections of the vehicle can be controlled either collectively or separately.
The control unit features a compact design with a simple and intuitive user interface, enabling rapid operation under field conditions. Automatic and manual firing modes provide operational flexibility, while the Built-In Test (BIT) function supports system diagnostics, maintenance and readiness checks.
UMAY DC-4 System Features
Configurable Ammunition Channels
The number of controllable smoke grenade channels can be configured according to vehicle layout and customer requirements.
Directional Deployment
Smoke grenades positioned on left, right, front and rear sections can be controlled according to the required direction.
Collective or Separate Control
Vehicle-mounted smoke grenades can be controlled collectively or separately according to operational requirements.
Automatic & Manual Firing
The unit supports both automatic and manual smoke grenade launching modes.
Built-In Test (BIT)
BIT functionality supports system diagnostics, maintenance and readiness checks.
Laser Warning Integration
The control architecture supports coordination with laser warning systems when integrated.
Flexible Smoke Deployment Configuration
Left & Right Control
- Left
- Directional smoke deployment
- Right
- Directional smoke deployment
Front & Rear Control
- Front
- Directional smoke deployment
- Rear
- Directional smoke deployment
Firing Management
- Modes
- Automatic and manual
- Control
- Collective or separate
Defense and Security Applications
Configurable Directional Smoke Deployment
The number of ammunition channels is configurable according to vehicle layout and customer requirements rather than being defined as a fixed grenade-control capacity in the supplied product information.
Smoke grenades positioned on the left, right, front and rear sections of the vehicle can be controlled collectively or separately, while automatic and manual firing modes provide additional operational flexibility.
Built-In Diagnostics and Laser Warning Coordination
Built-In Test (BIT) functionality supports system diagnostics, maintenance and readiness checks during operational preparation and servicing.
The control unit is designed to support smoke launcher operation together with laser warning integration on military and law enforcement vehicle platforms.
Environmental and EMI / EMC Qualification
Smoke Launcher Control Unit UMAY DC-4 has successfully passed MIL-STD-810H environmental testing and MIL-STD-461 EMI / EMC testing.
These test results verify reliable operation under harsh environmental and electromagnetic conditions.
Command and Control for Directional Smoke Deployment
UMAY DC-4 functions as the command and control interface for smoke grenade launcher systems, enabling directional smoke deployment and integration with vehicle protection systems.
By supporting flexible firing configurations and built-in diagnostics, the unit enhances vehicle survivability and operational effectiveness in military and public order operations.
Frequently Asked Questions
01How many smoke grenades can UMAY DC-4 control?
The number of controllable smoke grenades depends on vehicle integration and launcher placement, and can be configured according to operational requirements.
02Does UMAY DC-4 support automatic and manual firing modes?
Yes. The control unit supports both automatic and manual smoke grenade launching modes.
03Can smoke grenades be fired directionally?
Yes. Smoke grenades placed on left, right, front and rear sections of the vehicle can be controlled separately or collectively.
04Does the control unit support system diagnostics?
Yes. UMAY DC-4 includes a Built-In Test (BIT) function for system monitoring and maintenance checks.
05Is UMAY DC-4 suitable for harsh operational environments?
Yes. The unit has successfully passed MIL-STD-810H environmental tests and MIL-STD-461 EMI/EMC tests.
Technical Data
Need More Information About UMAY DC-4?
Contact our team for smoke launcher control, directional firing configuration and vehicle protection integration requirements.