Air Measuring Device

Laser-Based Particle Measurement Air Measuring Device AIR MEASURING DEVICE / REAL-TIME PM ANALYSIS
Airborne Particle Monitoring

Air Measuring Device

Air Measuring Device is a laser-based particle measurement system designed to analyze airborne particulate matter in real time. The device measures particle size and concentration within sampled airflow and provides continuous particulate-mass monitoring for biological detection and air-quality assessment in controlled and operational environments.

Detection Range 0.3 – 10 µm
Mass Concentration 0 – 1000 µg/m³
Sampling Duration 1 ± 0.04 sec
Operating Voltage 24V DC

Real-time PM1, PM2.5, PM4 and PM10 analysis using laser-based particle sensing and continuous sampled-air measurement.

Real-Time Airborne Particle Measurement

The Air Measuring Device is developed to measure and analyze airborne particles by detecting light scattered from individual particles passing through a laser beam.

The resulting measurement data is used to determine particle-size distribution and particle concentration, enabling calculation of particulate mass values for PM1, PM2.5, PM4 and PM10 classifications.

01 / DEPLOYMENT

Fixed and Mobile Airborne Particle Monitoring

The device is deployed in biological detection systems, CBRN-related monitoring applications, vehicle-mounted protection systems, shelters and controlled environments where continuous airborne particle measurement is required.

It is suitable for both fixed and mobile applications supporting situational awareness, environmental monitoring and real-time air-quality assessment.

Particle
Range
0.3
– 10 µm

Laser Scattering Measurement Principle

The system measures particles with diameters ranging from 0.3 µm to 10 µm using a laser-based particle sensor. Individual particles carried within sampled airflow pass through a laser beam and the device analyzes the light scattered by those particles.

Particle mass concentrations are calculated from particle-size spectra and concentration data using assumed particle-density and refraction-index values. This enables detailed interpretation of particulate loads in the measured air.

Measurement Structure

Particle Detection and Real-Time Analysis Features

01

Laser-Based Particle Sensor

Particle size and concentration are determined by analyzing light scattered from individual airborne particles passing through a laser beam.

02

0.3 – 10 µm Detection Range

The measurement system detects airborne particles across the stated 0.3 µm to 10 µm particle-diameter range.

03

PM1 / PM2.5 / PM4 / PM10

The integrated LCD display provides real-time visualization of PM1, PM2.5, PM4 and PM10 mass-concentration values.

04

Continuous Sampling

Continuous sampled-air measurement supports ongoing observation of airborne particulate loads in operational and controlled environments.

05

Real-Time LCD Display

An integrated LCD display enables direct observation of particulate-matter values and particle-size distribution during operation.

06

Fixed & Mobile Integration

The device is suitable for fixed installations and mobile platforms requiring continuous particulate measurement and environmental monitoring.

Measurement Architecture

Sampling, Particle Analysis and PM Classification

SENSING / 01

Laser Particle Detection

Principle
Scattered Light Analysis
Particle Range
0.3 – 10 µm
Sampling
Continuous
ANALYSIS / 02

Mass Concentration

Range
0 – 1000 µg/m³
Calculation
Size Spectrum & Concentration
Parameters
Density & Refraction Index
OUTPUT / 03

Particulate Classification

PM1
Displayed
PM2.5 / PM4
Displayed
PM10
Displayed
Deployment Areas

Monitoring Applications

Biological Detection Systems
CBRN Monitoring Applications
Vehicle-Mounted Protection Systems
Shelters
Controlled Environments
Fixed & Mobile Monitoring
02 / REAL-TIME DISPLAY

Integrated LCD Particulate Visualization

The integrated LCD display provides clear visualization of PM1, PM2.5, PM4 and PM10 values, enabling real-time observation of particle-size distribution and particulate mass concentration.

The device therefore provides direct measurement output for environmental assessment, air-quality monitoring and CBRN-related detection-system integration.

Test & Certification Framework

Measurement and Operating Framework

The supplied product information does not identify a specific NATO, MIL-STD or civilian certification for this device. It describes the unit as designed for reliable operation across varying environmental conditions while supporting continuous sampling and measurement under changing temperature and humidity levels.

Its sensing methodology and structure are intended for integration into advanced detection and monitoring systems requiring stable and repeatable particulate analysis.

Laser-Based Particle Measurement Optical Particle Sensing
0.3 – 10 µm Detection Range Particle Diameter Measurement
Continuous Sampling Ongoing Airborne Particle Monitoring
Real-Time PM Analysis PM1 / PM2.5 / PM4 / PM10
03 / FUNCTIONAL ROLE

Continuous Particulate Monitoring and Mass-Concentration Analysis

The Air Measuring Device continuously monitors airborne particulate matter and provides real-time data on particle size and mass concentration.

By distinguishing between PM1, PM2.5, PM4 and PM10 fractions, it supports biological detection, environmental assessment and air-quality monitoring functions within CBRN-related systems and protected environments.

FAQ / 05

Frequently Asked Questions

01 What particle size range does the Air Measuring Device detect?

The device detects airborne particles with diameters between 0.3 µm and 10 µm.

02 Which particulate matter values are displayed by the system?

It displays PM1, PM2.5, PM4 and PM10 mass-concentration values on the LCD screen.

03 How does the measurement principle work?

The system measures light scattered by individual particles passing through a laser beam to determine particle size and concentration.

04 In which applications can the Air Measuring Device be used?

It is used in biological detection systems, CBRN monitoring applications, vehicle-mounted systems and controlled environments requiring real-time air-quality measurement.

05 Can the Air Measuring Device be used in both fixed and mobile applications?

Yes. The device is suitable for both fixed and mobile applications requiring continuous airborne particle measurement and environmental monitoring.

Air Measuring Device Specifications

Technical Data

Mass Concentration Range 0 – 1000 µg/m³
Mass Concentration Size Range PM1.0: 0.3 – 10 µm
PM2.5: 0.3 – 2.5 µm
PM4: 0.3 – 4 µm
PM10: 0.3 – 10 µm
Mass Concentration Sensitivity PM1 & PM2.5 0 – 100 µg/m³ ±10
100 – 1000 µg/m³ ±10
Mass Concentration Sensitivity PM4 & PM10 0 – 100 µg/m³ ±25
0 – 1000 µg/m³ ±25
Annual Sensitivity Loss 0 – 100 µg/m³/year ±1.25
100 – 1000 µg/m³/year ±1.25
Sampling Duration 1 ± 0.04 sec
Operating Voltage 24V DC
Current Value (Max.) 2A
Operating Temperature -32 / +49 °C
Operating Humidity Range 0 – 96 %RH
Dimensions 212 x 235 x 264 mm
Weight 51 g
Fire Bulgaria / Product Support

Need More Information About the Air Measuring Device?

Contact our team for particle-measurement integration, biological-detection applications, CBRN monitoring and fixed or mobile air-analysis requirements.

Request Information