Air Measuring Device
AIR MEASURING DEVICE / REAL-TIME PM ANALYSIS
Air Measuring Device
Air Measuring Device is a laser-based particle measurement system designed to analyze airborne particulate matter in real time. The device measures particle size and concentration within sampled airflow and provides continuous particulate-mass monitoring for biological detection and air-quality assessment in controlled and operational environments.
Real-time PM1, PM2.5, PM4 and PM10 analysis using laser-based particle sensing and continuous sampled-air measurement.
Real-Time Airborne Particle Measurement
The Air Measuring Device is developed to measure and analyze airborne particles by detecting light scattered from individual particles passing through a laser beam.
The resulting measurement data is used to determine particle-size distribution and particle concentration, enabling calculation of particulate mass values for PM1, PM2.5, PM4 and PM10 classifications.
Fixed and Mobile Airborne Particle Monitoring
The device is deployed in biological detection systems, CBRN-related monitoring applications, vehicle-mounted protection systems, shelters and controlled environments where continuous airborne particle measurement is required.
It is suitable for both fixed and mobile applications supporting situational awareness, environmental monitoring and real-time air-quality assessment.
Range 0.3
– 10 µm
Laser Scattering Measurement Principle
The system measures particles with diameters ranging from 0.3 µm to 10 µm using a laser-based particle sensor. Individual particles carried within sampled airflow pass through a laser beam and the device analyzes the light scattered by those particles.
Particle mass concentrations are calculated from particle-size spectra and concentration data using assumed particle-density and refraction-index values. This enables detailed interpretation of particulate loads in the measured air.
Particle Detection and Real-Time Analysis Features
Laser-Based Particle Sensor
Particle size and concentration are determined by analyzing light scattered from individual airborne particles passing through a laser beam.
0.3 – 10 µm Detection Range
The measurement system detects airborne particles across the stated 0.3 µm to 10 µm particle-diameter range.
PM1 / PM2.5 / PM4 / PM10
The integrated LCD display provides real-time visualization of PM1, PM2.5, PM4 and PM10 mass-concentration values.
Continuous Sampling
Continuous sampled-air measurement supports ongoing observation of airborne particulate loads in operational and controlled environments.
Real-Time LCD Display
An integrated LCD display enables direct observation of particulate-matter values and particle-size distribution during operation.
Fixed & Mobile Integration
The device is suitable for fixed installations and mobile platforms requiring continuous particulate measurement and environmental monitoring.
Sampling, Particle Analysis and PM Classification
Laser Particle Detection
- Principle
- Scattered Light Analysis
- Particle Range
- 0.3 – 10 µm
- Sampling
- Continuous
Mass Concentration
- Range
- 0 – 1000 µg/m³
- Calculation
- Size Spectrum & Concentration
- Parameters
- Density & Refraction Index
Particulate Classification
- PM1
- Displayed
- PM2.5 / PM4
- Displayed
- PM10
- Displayed
Monitoring Applications
Integrated LCD Particulate Visualization
The integrated LCD display provides clear visualization of PM1, PM2.5, PM4 and PM10 values, enabling real-time observation of particle-size distribution and particulate mass concentration.
The device therefore provides direct measurement output for environmental assessment, air-quality monitoring and CBRN-related detection-system integration.
Measurement and Operating Framework
The supplied product information does not identify a specific NATO, MIL-STD or civilian certification for this device. It describes the unit as designed for reliable operation across varying environmental conditions while supporting continuous sampling and measurement under changing temperature and humidity levels.
Its sensing methodology and structure are intended for integration into advanced detection and monitoring systems requiring stable and repeatable particulate analysis.
Continuous Particulate Monitoring and Mass-Concentration Analysis
The Air Measuring Device continuously monitors airborne particulate matter and provides real-time data on particle size and mass concentration.
By distinguishing between PM1, PM2.5, PM4 and PM10 fractions, it supports biological detection, environmental assessment and air-quality monitoring functions within CBRN-related systems and protected environments.
Frequently Asked Questions
01 What particle size range does the Air Measuring Device detect?
The device detects airborne particles with diameters between 0.3 µm and 10 µm.
02 Which particulate matter values are displayed by the system?
It displays PM1, PM2.5, PM4 and PM10 mass-concentration values on the LCD screen.
03 How does the measurement principle work?
The system measures light scattered by individual particles passing through a laser beam to determine particle size and concentration.
04 In which applications can the Air Measuring Device be used?
It is used in biological detection systems, CBRN monitoring applications, vehicle-mounted systems and controlled environments requiring real-time air-quality measurement.
05 Can the Air Measuring Device be used in both fixed and mobile applications?
Yes. The device is suitable for both fixed and mobile applications requiring continuous airborne particle measurement and environmental monitoring.
Technical Data
PM2.5: 0.3 – 2.5 µm
PM4: 0.3 – 4 µm
PM10: 0.3 – 10 µm
100 – 1000 µg/m³ ±10
0 – 1000 µg/m³ ±25
100 – 1000 µg/m³/year ±1.25
Need More Information About the Air Measuring Device?
Contact our team for particle-measurement integration, biological-detection applications, CBRN monitoring and fixed or mobile air-analysis requirements.