Concentration Test Kit

Agent Concentration Measurement Concentration Test Kit TEST KIT / MULTI-POINT MEASUREMENT

Concentration Test Kit

The Concentration Test Kit measures the extinguishing-agent concentration produced inside a vehicle after activation of fire suppression or explosion suppression systems. The test procedure is based on the concentration test defined in NATO STANAG 4317 Section 4.4.3, while HFC227ea reference values specified in NFPA 2001 are used for evaluation. Multi-point measurement allows the resulting concentration profile to be documented across occupied or enclosed vehicle compartments.

Sampling Rate> 100 Hz
Measurement Range0%–25%
Measurement PointsUp to 10
Operating Temperature0°C–40°C

Multi-point concentration measurement equipment for post-discharge verification in vehicle fire suppression and explosion suppression applications.

Multi-Point Gas Concentration Verification After System Discharge

The Concentration Test Kit is intended for measuring the extinguishing-agent concentration that develops inside a vehicle or enclosed compartment after a suppression-system discharge. The resulting data provides a basis for evaluating the post-discharge environment against the referenced HFC227ea concentration values.

This measurement approach supports acceptance testing, design verification and personnel-exposure assessment for vehicle fire suppression and explosion suppression installations.

01 / MEASUREMENT SETUP

Simultaneous Measurement Across Multiple Vehicle Locations

Before cylinder discharge, sensors are positioned at a minimum of three and a maximum of ten locations inside the vehicle. The system is configured to acquire concentration measurements from multiple points at the same time.

After discharge, the sensors collect averaged data over a 30-second sampling period, while the complete measurement sequence continues for 5 minutes.

Measurement
Method
3–10
Points

Light-Intensity-Based Concentration Measurement

The supplied test description specifies a light intensity–based measurement method for determining gas concentration at each sensor location. This allows concentration values to be captured across different positions within the protected compartment after extinguishing-agent release.

The technical data specifies a measurement range of 0%–25% and a sampling rate greater than 100 Hz, identified as the fast-sensor category according to STANAG 4317.

Measurement Functions

Concentration Test Kit Highlights

01

Multi-Point Measurement

Supports simultaneous concentration measurement at up to ten locations inside the vehicle or enclosed compartment.

02

> 100 Hz Sampling Rate

The specified sampling rate exceeds 100 Hz and is identified as the fast-sensor category according to STANAG 4317.

03

0%–25% Measurement Range

Measures gas concentration across the specified 0% to 25% range during post-discharge verification.

04

30-Second Averaging Period

Sensor data is averaged over a 30-second sampling period following extinguishing-cylinder discharge.

05

5-Minute Test Duration

The supplied procedure defines a total concentration measurement duration of five minutes.

06

HFC227ea Reference Evaluation

Measured concentration data is evaluated using the HFC227ea reference values specified under NFPA 2001.

Verification Process

Sensor Placement, Sampling and Result Evaluation

STAGE / 01

Sensor Placement

Minimum
3 measurement locations.
Maximum
10 measurement locations.
Timing
Sensors are positioned before cylinder discharge.
STAGE / 02

Post-Discharge Sampling

Averaging Period
30 seconds.
Total Duration
5 minutes.
Method
Light-intensity-based gas concentration measurement.
STAGE / 03

Concentration Assessment

Procedure
NATO STANAG 4317 Section 4.4.3.
Agent Reference
HFC227ea.
Evaluation Reference
NFPA 2001 concentration values.
Verification Use

Application Areas

Military Vehicle Suppression Systems
Enclosed Personnel Compartments
Fire Suppression System Acceptance Tests
Explosion Suppression System Verification
System Design Validation
Personnel Exposure Assessment
Referenced Test Framework

Concentration Test Standards

The supplied test procedure identifies NATO STANAG 4317 Section 4.4.3 as the basis for the concentration test. For measurement evaluation, the HFC227ea concentration reference values in NFPA 2001 are used. These references define the framework stated for conducting and assessing the supplied concentration test procedure.

NATO STANAG 4317
Section 4.4.3
NFPA 2001
HFC227ea Reference Values
FAQ / PRODUCT

Frequently Asked Questions

01How many measurement locations can be monitored during one test?

The described test setup uses sensors at a minimum of three and a maximum of ten locations, with simultaneous multi-point measurement capability.

02What concentration range can the test kit measure?

The supplied technical data specifies a measurement range of 0%–25%.

03What sampling performance is specified for the sensors?

The sampling rate is specified as greater than 100 Hz, described as the fast-sensor category according to STANAG 4317.

04How long does the post-discharge measurement sequence continue?

Sensor data is averaged over a 30-second sampling period, and the stated total measurement duration is 5 minutes.

05What operating temperature range is specified for the kit?

The technical data specifies an operating temperature range of 0°C to 40°C.

Concentration Test Kit Specifications

Technical Data

Sampling Rate> 100 Hz
Sensor CategoryFast Sensor / STANAG 4317
Measurement Range0%–25%
Operating Temperature0°C–40°C
Measurement CapabilityUp to 10 Points
Minimum Sensor Locations3 Points
Sampling / Averaging Period30 Seconds
Total Measurement Duration5 Minutes
Measurement MethodLight Intensity Based
Test Procedure ReferenceSTANAG 4317 §4.4.3
Evaluation ReferenceNFPA 2001
Agent ReferenceHFC227ea