Military Generator 15 kVA – G15M
G15M / 15 KVA FIELD POWER Military Generator 15 kVA – G15M
The Military Generator 15 kVA – G15M is a deployable power generation solution developed for demanding military applications where multiple electrical systems may need dependable energy beyond stable grid infrastructure. Its rugged field-oriented construction supports high-consumption equipment used in communications, medical support, radar, emergency response and other mission-critical operational roles.
Deployable 15 kVA military generator platform for high-demand field power, mission-support equipment and sustained operational use.
Higher-Capacity Field Power for Mission-Critical Systems
The Military Generator 15 kVA – G15M is intended for military operations where energy-intensive equipment must remain available when grid power is unavailable, unstable or disrupted. Its field-oriented construction combines deployability with the durability required for demanding operational environments.
Configuration options may differ in fuel type, acoustic characteristics, portability level, dimensions, weight and installation requirements. Gasoline and diesel operation are identified as configuration-dependent options, with individual variants tailored to different mission profiles.
Power Availability for Deployed Military Infrastructure
The G15M is identified as a 15 kVA military generator. Separately, the supplied technical data table lists 5 kW output power, 7 kW continuous power, a maximum current of 20 A, and 220 VAC / 380 VAC output voltage. These values are presented independently as supplied.
The generator can automatically activate if the main power supply to equipment shelters is interrupted. A military-grade AGM battery with a minimum capacity of 40 Ah supports startup, including ambient temperatures down to −32°C when used with a pre-heater.
Power7
kW
Field Endurance with Integrated Protection Functions
Automatic protection mechanisms are described for overload, overheating, low fuel level and abnormal operating conditions. The technical data specifies a water-cooled system and a sound level of 75 dB at 7 m.
The supplied operational description states a minimum of eight hours of full-load operation using the internal fuel tank without refueling. Electrical connectors are identified according to MIL-DTL-38999 and/or VG95234. The control board is separately stated to have IP67 protection, while the generator's technical data lists the overall protection level as IP23.
G15M Field Power Features
High-Demand Field Power
The G15M is positioned for military applications requiring electrical support for energy-intensive mission equipment.
Deployable Construction
Its field-oriented design supports deployment and relocation according to changing operational requirements.
Automatic Power-Loss Start
The generator can activate automatically when primary electrical power to supported equipment shelters is interrupted.
Eight-Hour Full-Load Endurance
The supplied information states at least eight hours of full-load operation from the internal fuel tank without refueling.
Automatic Protection Functions
Shutdown protection is described for overload, overheating, low fuel level and other abnormal operating conditions.
IP67 Control Board Protection
The control board is separately identified with IP67 protection against dust and water ingress.
Mission-Oriented G15M Configurations
Fuel Configuration
- Options
- Gasoline or diesel depending on configuration.
- Selection
- Defined according to mission and operating requirements.
- Role
- Supports adaptation to different field power scenarios.
Deployment Configuration
- Immediate Use
- Selected configurations are intended for operation without installation.
- Assembly
- Other configurations may require assembly before deployment.
- Variation
- Portability, dimensions, weight and installation needs may differ.
Operational Configuration
- Noise
- Certain configurations support reduced-noise operation.
- Control
- A simplified control panel supports field operation.
- Cooling
- Water-cooled system specified in the technical data.
Operational Applications
Environmental, Reliability and Electrical References
The supplied product information lists military standards addressing environmental durability, reliability, electromagnetic compatibility and electrical power requirements. Military electrical connector references are separately stated as MIL-DTL-38999 and/or VG95234.
Frequently Asked Questions
01Which output voltages are listed for the G15M?
The supplied technical table lists 220 VAC and 380 VAC as the output voltage values.
02What is the listed system weight of the G15M?
The technical data specifies a system weight of 700 kg ±5.
03What maximum operating elevation is specified?
The supplied specifications list a maximum operating elevation of 3000 m.
04Which communication connections are listed for the generator?
The technical table identifies RS422 and TCP as the listed connection types.
05What dimensions are specified for the G15M?
The supplied dimensions are 914 × 1260 × 1110 mm ±5.
Technical Data
Need More Information About the Military Generator 15 kVA – G15M?
Contact our team for G15M configuration, deployment and military field power requirements.