Military Generator 22,5 kVA – G22D
G22D / 22.5 KVA FIELD POWER Military Generator 22.5 kVA – G22D
The Military Generator 22.5 kVA – G22D is a deployable power generation solution developed for demanding military applications where high-consumption equipment requires dependable electrical supply beyond stable grid infrastructure. Its rugged field-oriented construction supports communications, medical equipment, radar systems, emergency-response equipment and other mission-critical electrical loads in challenging operational environments.
Deployable 22.5 kVA military generator platform for high-capacity field power, mission-support equipment and sustained operational use.
High-Capacity Field Power for Demanding Military Systems
The Military Generator 22.5 kVA – G22D is intended for operational environments where high-consumption electrical equipment must remain available when grid power is unavailable, unstable or compromised. Its rugged construction combines higher power capacity with field deployment capability for military and emergency-response roles.
Available configurations may vary by fuel type, acoustic characteristics, portability, physical dimensions, weight and installation requirements. Gasoline and diesel operation are identified as configuration-dependent options, allowing individual variants to address different operational requirements.
Sustained Electrical Support Beyond Fixed Infrastructure
The G22D is specified with 22.5 kVA output power and 18.5 kVA continuous power. The supplied technical data additionally lists 380 VAC output voltage and a maximum current of 16 A.
The generator can automatically activate when the main electrical supply to equipment shelters is interrupted. A military-grade AGM battery with a minimum capacity of 40 Ah supports startup, including ambient temperatures down to −32°C when supported by a pre-heater.
Power18.5
kVA
Extended Field Operation with Automatic Protection
The supplied product information describes automatic shutdown functions for overload, overheating, low fuel level and abnormal operating conditions. The technical specifications identify a water-cooled system and a sound level of 75 dB at 7 m.
At full load, the generator is stated to operate for a minimum of eight hours from its internal fuel tank without refueling. Electrical connectors are identified according to MIL-DTL-38999 and/or VG95234. The control board is separately stated to have IP67 protection, while the overall generator protection level in the technical table is IP23.
G22D Field Power Features
22.5 kVA Output Power
The supplied technical data specifies 22.5 kVA output power for demanding deployed electrical applications.
18.5 kVA Continuous Power
Continuous power is listed as 18.5 kVA for sustained support of operational electrical loads.
Automatic Power-Loss Start
The generator can activate automatically following interruption of the primary supply to supported equipment shelters.
Eight-Hour Full-Load Endurance
The supplied information states at least eight hours of full-load operation from the internal fuel tank without refueling.
Automatic Protection Functions
Shutdown protection is described for overload, overheating, low fuel level and other abnormal operating conditions.
IP67 Control Board Protection
The control board is separately identified with IP67 protection against dust and water ingress.
Mission-Oriented G22D Configurations
Fuel Configuration
- Options
- Gasoline or diesel depending on configuration.
- Selection
- Defined according to mission and operating requirements.
- Purpose
- Adaptation to different deployed power scenarios.
Deployment Configuration
- Immediate Use
- Selected variants are intended for operation without installation.
- Assembly
- Other variants may require assembly before deployment.
- Variation
- Portability, dimensions, weight and installation requirements may differ.
Operational Configuration
- Noise
- Certain configurations support reduced-noise operation.
- Control
- A simplified control panel supports efficient field use.
- Cooling
- Water-cooled system specified in the technical data.
Operational Applications
Environmental, Reliability and Electrical References
The supplied product information lists military standards addressing environmental durability, reliability, electromagnetic compatibility and electrical power requirements. Military electrical connector references are separately stated as MIL-DTL-38999 and/or VG95234.
Frequently Asked Questions
01What continuous power value is specified for the G22D?
The supplied technical data lists 18.5 kVA continuous power.
02What output voltage is listed for the G22D?
The technical table specifies an output voltage of 380 VAC.
03What is the listed system weight of the G22D?
The supplied technical data specifies a system weight of 1000 kg ±5.
04What fuel consumption value is provided for the generator?
The supplied specifications list fuel consumption as 8.6 L/H.
05What dimensions are provided for the G22D?
The supplied dimensions are 2456 × 678 × 1734 mm ±5.
Technical Data
Need More Information About the Military Generator 22.5 kVA – G22D?
Contact our team for G22D configuration, deployment and military field power requirements.