Portable Military Power Military Generator 25 kVA G25DM G25DM / 25 KVA DIESEL POWER

Military Generator 25 kVA – G25DM

The Military Generator 25 kVA – G25DM is a diesel-powered deployable generation solution developed for demanding military applications where mission-critical equipment requires dependable electrical supply beyond stable grid infrastructure. Its rugged field-oriented construction supports communications, medical equipment, radar systems, emergency-response equipment and other high-demand electrical loads in challenging operational environments.

Output Power25 kVA
Continuous Power20 kVA
Output Voltage220 VAC
Fuel TypeDiesel

Deployable 25 kVA diesel military generator platform for high-capacity field power, mission-support equipment and sustained operational use.

Diesel Field Power for Mission-Critical Military Systems

The Military Generator 25 kVA – G25DM is intended for operational environments where high-consumption electrical equipment must remain available when fixed grid power is unavailable, unstable or compromised. Its diesel-powered architecture combines high-capacity generation with a rugged structure suited to field deployment and repositioning.

The generator is offered in configurations that may vary by noise characteristics, portability, physical dimensions, weight and installation requirements. Some variants are intended for immediate operation, while others may require assembly before deployment.

01 / DIESEL POWER

Sustained Electrical Support Beyond Fixed Infrastructure

The G25DM is specified with 25 kVA output power and 20 kVA continuous power. The supplied technical data additionally lists 220 VAC output voltage and a maximum current of 16 A.

The generator can automatically activate when the main electrical supply to equipment shelters is interrupted. A military-grade AGM battery with a minimum capacity of 40 Ah supports startup, including ambient temperatures down to −32°C when supported by a pre-heater.

Continuous
Power
20
kVA

Extended Field Operation with Automatic Protection

The supplied product information describes automatic shutdown functions for overload, overheating, low fuel level and abnormal operating conditions. The technical specifications identify a water-cooled system and a sound level of 75 dB at 7 m.

At full load, the generator is stated to operate for a minimum of eight hours from its internal fuel tank without refueling. Electrical connectors are identified according to MIL-DTL-38999 and/or VG95234. The control board is separately stated to have IP67 protection, while the overall generator protection level in the technical table is IP23.

Operational Characteristics

G25DM Field Power Features

01

25 kVA Output Power

The supplied technical data specifies 25 kVA output power for demanding deployed electrical applications.

02

20 kVA Continuous Power

Continuous power is listed as 20 kVA for sustained support of operational electrical loads.

03

Diesel Operation

The G25DM is identified as a diesel-powered generator for military field applications.

04

Eight-Hour Full-Load Endurance

The supplied information states at least eight hours of full-load operation from the internal fuel tank without refueling.

05

Automatic Protection Functions

Shutdown protection is described for overload, overheating, low fuel level and other abnormal operating conditions.

06

IP67 Control Board Protection

The control board is separately identified with IP67 protection against dust and water ingress.

Configuration

Mission-Oriented G25DM Configuration

CONFIG / 01

Diesel Power Configuration

Fuel
Diesel.
Output
25 kVA rated output power.
Continuous Power
20 kVA.
CONFIG / 02

Deployment Configuration

Immediate Use
Selected variants are intended for operation without installation.
Assembly
Other variants may require assembly before deployment.
Variation
Portability, dimensions, weight and installation requirements may differ.
CONFIG / 03

Operational Configuration

Noise
Certain configurations support reduced-noise operation.
Control
A simplified control panel supports efficient field use.
Cooling
Water-cooled system specified in the technical data.
Deployment Areas

Operational Applications

Mobile Military Units
Ground and Air Vehicle Support
Communication Infrastructure
Medical Equipment
Radar Systems
Emergency Response Operations
Military Standards & Testing

Environmental, Reliability and Electrical References

The supplied product information lists military standards addressing environmental durability, reliability, electromagnetic compatibility and electrical power requirements. Military electrical connector references are separately stated as MIL-DTL-38999 and/or VG95234.

MIL-STD-810
MIL-HDBK-217F
MIL-STD-461F
MIL-STD-704F
FAQ / PRODUCT

Frequently Asked Questions

01What continuous power value is specified for the G25DM?

The supplied technical data lists 20 kVA continuous power.

02What output voltage is listed for the G25DM?

The technical table specifies an output voltage of 220 VAC.

03What is the listed system weight of the G25DM?

The supplied technical data specifies a system weight of 800 kg ±5.

04What fuel consumption value is specified?

The supplied specifications list fuel consumption as 6.1 L/H.

05What dimensions are provided for the G25DM?

The supplied dimensions are 1655 × 793 × 1318 mm ±5.

Military Generator 25 kVA – G25DM Specifications

Technical Data

Output Power25 kVA
Output Voltage220 VAC
Continuous Power20 kVA
Maximum Ampere16 A
Operating Temperature-32 / +49 °C
Storage Temperature-40°C ~ +60°C
Integrated Cooling SystemWater Cooled
Sound Level75 dB @ 7 m
Maximum Operating Elevation3000 m
Protection LevelIP23
System Weight800 kg ±5
Fuel Consumption6.1 L/H
Connection TypeRS422, TCP
Dimensions1655 × 793 × 1318 mm ±5
Fire Bulgaria / Product Support