Military Generator 3 kVA – G3M

Portable Military Power Military Generator 3 kVA G3M G3M / 3 KVA FIELD POWER

Military Generator 3 kVA – G3M

The Military Generator 3 kVA – G3M is a compact field power unit developed for military and mission-support applications where dependable electrical supply must be maintained away from fixed infrastructure. With 3 kVA output power, 220 VAC single-phase delivery and a portable configuration, the G3M supports communications, emergency equipment, medical devices and other operational electronics across demanding deployment environments.

Output Power3 kVA
Continuous Power2.5 kVA
Output Voltage220 VAC
Protection LevelIP23

Portable 3 kVA military generator for field power continuity, mobile deployment and mission-support electrical loads.

Portable Electrical Power for Field and Mission-Support Operations

The Military Generator 3 kVA – G3M provides a deployable source of electrical power for equipment operating where fixed infrastructure is unavailable, interrupted or unsuitable for the mission. Its compact construction and carrying-oriented configuration support movement between operational locations.

The generator can be configured for gasoline or diesel fuel depending on operational requirements, while selected variants may differ in noise level, portability, dimensions, weight and installation needs.

01 / FIELD PERFORMANCE

Power Continuity for Deployed Equipment

The G3M delivers a 3 kVA output rating with 2.5 kVA continuous power and a 220 VAC output. The supplied product information also states that the generator can run at full load for a minimum of eight hours from its internal fuel tank without refueling.

For shelter-related use, the generator can automatically activate when the external electrical supply is interrupted. A military-grade AGM battery with a minimum capacity of 40 Ah supports starting, including operation at ambient temperatures down to −32°C when used with a pre-heater.

Rated
Output
3
kVA

Compact Power Generation with Integrated Protection Functions

The G3M combines field-oriented power generation with automatic protective functions intended to stop operation during overload, overheating or other abnormal conditions. The supplied configuration information also identifies water cooling and a sound level of 75 dB at 7 m.

Electrical connections are specified according to MIL-DTL-38999 and/or VG95234, supporting secure connection interfaces for military field environments.

Operational Characteristics

G3M Field Power Features

01

3 kVA Rated Output

Provides 3 kVA output power with 2.5 kVA continuous power for deployed electrical equipment.

02

Portable Deployment

Compact construction and integrated carrying features support transport and rapid positioning in field conditions.

03

Automatic Power-Loss Start

Can activate automatically when the external supply to supported equipment shelters is interrupted.

04

Extended Full-Load Operation

The supplied product information states a minimum of eight hours of full-load operation using the internal fuel tank.

05

Automatic Protection

Protection mechanisms shut down the system in overload, overheating or other stated abnormal operating conditions.

06

Field Communication Interface

The technical data specifies RS422 – TCP as the connection type for the generator system.

Configuration

Mission-Oriented Generator Configurations

CONFIG / 01

Fuel Configuration

Options
Gasoline or diesel depending on configuration.
Selection
Defined according to operational requirements.
CONFIG / 02

Deployment Configuration

Portable Use
Configurations may be prepared for immediate field deployment.
Assembly
Other variants may require assembly before operation.
CONFIG / 03

Operational Configuration

Noise
Certain configurations support low-noise operation.
Cooling
Water-cooled system specified in the technical data.
Deployment Areas

Field Applications

Mobile Military Units
Ground and Air Vehicle Support
Communication Systems
Medical Equipment
Radar and Mission Electronics
Emergency Response Operations
Referenced Military Standards

Environmental, Reliability and Electrical References

The supplied product information lists the following military standards for the G3M generator. They cover environmental testing, reliability prediction, electromagnetic compatibility and military electrical power characteristics. Connector references are separately stated as MIL-DTL-38999 and/or VG95234.

MIL-STD-810
MIL-HDBK-217F
MIL-STD-461F
MIL-STD-704F
FAQ / PRODUCT

Frequently Asked Questions

01What continuous power rating is specified for the G3M?

The technical data specifies 2.5 kVA continuous power, with a rated output power of 3 kVA.

02What output voltage does the generator provide?

The G3M is specified with a 220 VAC output. The supplied product description identifies the output as single-phase at 50 Hz.

03What are the stated temperature limits for operation and storage?

The operating temperature range is −32°C to +55°C, while the storage temperature range is −40°C to +60°C.

04What maximum operating elevation is listed for the G3M?

The technical data lists a maximum operating elevation of 3000 m.

05Which electrical connection standards are specified for field interfaces?

The supplied product information states that electrical connectors are manufactured according to MIL-DTL-38999 and/or VG95234.

Military Generator 3 kVA – G3M Specifications

Technical Data

Output Power3 kVA
Output Voltage220 VAC
Continuous Power2.5 kVA
Maximum Ampere16 A
Operating Temperature−32°C ~ +55°C
Storage Temperature−40°C ~ +60°C
Integrated Cooling SystemWater Cooled
Sound Level75 dB @ 7 m
Maximum Operating Elevation3000 m
Protection LevelIP23
System Weight156 kg ±5
Connection TypeRS422 – TCP
Fuel Consumption3 L/s
Dimensions882 × 525 × 603 mm ±5