Pyrex-XL Gas Agent Extinguisher

Fire Suppression Pyrex-XL Gas Agent Extinguisher PYREX-XL / GAS AGENT

Pyrex-XL Gas Agent Extinguisher

Designed for demanding protected platforms, Pyrex-XL combines increased extinguishing capacity with fast activation and installation flexibility for applications where available space and fire risk must be managed together.

Extinguishing Agent HFC-227ea
Nominal Pressure 60 Bar
Reaction Time < 6 ms
Cylinder Capacity 8–15 kg

A higher-capacity gas-agent solution for protected platforms, sensitive equipment zones and demanding fire-risk environments.

Higher-Capacity Protection for Space-Constrained Systems

Designed for demanding protected platforms, Pyrex-XL combines increased extinguishing capacity with fast activation and installation flexibility for applications where available space and fire risk must be managed together. In environments where internal volume is limited and fire risks are severe, traditional fixed fire extinguishing systems can restrict vehicle layout and integration efficiency.

Pyrex-XL Gas Agent Extinguisher addresses this requirement with a higher-capacity gas-agent configuration developed for demanding operational environments. Its architecture supports flexible integration while retaining the rapid-response characteristics required for critical fire protection applications.

01 / OPERATION

Rapid Suppression for Critical Vehicle Fire Events

Rapid intervention is a central requirement in vehicle fire protection. Pyrex-XL is configured to provide suppression performance within the activation duration defined by NATO STANAG 4317, allowing the system to react within the required operational response window.

Where the cylinder cannot be positioned directly beside the protected zone, the discharge path can be routed toward the required fire-risk area. The hose configuration supports extensions of up to 2 meters, providing additional freedom when arranging suppression components inside restricted vehicle layouts.

Primary
Extinguishing Agent
HFC
227ea

Gas-Agent Suppression for Sensitive Compartments

Pyrex-XL can be configured around gaseous extinguishing technologies including CO₂, HFC-227ea (FM-200) and Inergen, allowing the suppression approach to be matched to the protected environment and system requirement.

Because these agents suppress fire without relying on conventional powder-based discharge, they are relevant to enclosed compartments and areas containing sensitive electrical, electronic or mission-critical equipment.

Product Advantages

Pyrex-XL Performance Highlights

01

High Suppression Capacity

The 8–15 kg cylinder range provides increased agent capacity for applications requiring a larger suppression reserve.

02

Rapid Response

A pyrotechnic activation mechanism supports fast initiation when an extinguishing command is received.

03

Clean Agent Technology

Gaseous suppression helps protect sensitive equipment without introducing powder-based extinguishing residue into the protected compartment.

04

Flexible Discharge

The discharge arrangement can route the extinguishing agent toward critical zones while allowing the cylinder to be positioned according to available installation space.

05

Lightweight Construction

Aluminum construction helps control system weight while supporting integration into mobile and protected platform applications.

06

Wide Environmental Capability

The specified operating range of -55°C to +70°C supports use across demanding environmental conditions.

Agent Options

Available Gas-Agent Configurations

TYPE / 01

CO₂ Fire Extinguishers

Agent
Carbon dioxide (CO₂)
Suppression Principle
Displaces oxygen to suppress combustion.
Typical Use
Electrical fires and confined spaces.
TYPE / 02

Inergen Fire Extinguishers

Agent
HFC-227ea (FM-200)
Suppression Principle
Reduces oxygen concentration within the protected area.
Typical Use
Data centers, archive rooms and sensitive technical environments.
TYPE / 03

HFC-227ea / FM-200 Fire Extinguishers

Agent
Inert gas mixture
Suppression Principle
Heat absorption with secondary chemical flame inhibition.
Typical Use
High-risk areas with flammable materials and electronic equipment.
Operational Use

Application Areas

Bank Vaults & Secure Storage
Archives & Rare Book Storage
Communication Centers
Control Rooms & Data Facilities
Marine & Naval Systems
Military & Armored Vehicles
Compliance

Standards & Qualification Framework

Pyrex-XL is specified against recognized fire-suppression and military environmental requirements. The listed standards provide the reference framework for clean-agent system performance, equipment qualification and operation under demanding service conditions.

NFPA 2001
ISO 14520
UL 2127
EN 15004
MIL-STD-810H
FAQ / PRODUCT

Frequently Asked Questions

01 What cylinder capacities are available for the Pyrex-XL system?

Pyrex-XL is available with cylinder capacities ranging from 8 to 15 kg, providing different configuration options according to the required suppression capacity.

02 How quickly does Pyrex-XL respond after activation?

The system provides a high-speed reaction time of less than 6 milliseconds, supporting rapid intervention in critical fire scenarios.

03 What pressure does the Pyrex-XL cylinder operate at?

Pyrex-XL has a nominal cylinder pressure of 60 Bar and uses dry nitrogen for super pressurisation.

04 Can Pyrex-XL be used in harsh environmental conditions?

Yes. Its specified operating temperature range is -55°C to +70°C, and the system is associated with military qualification requirements including MIL-STD-810H.

05 Can the Pyrex-XL extinguisher be refilled after discharge?

Yes. The technical configuration is designed to be refillable using a refill kit, supporting continued system use following the required servicing procedures.

Product Specifications

Technical Data

Extinguishing Agent HFC-227ea
Nominal Pressure 60 Bar
Reaction Time < 6 ms
Protection Level IP67
Cylinder Capacity 8–15 kg
Super Pressurisation Dry Nitrogen
Distribution Pattern 360° Homogeneous Distribution
Pressure Indicator Integrated Pressure Indicator
Operating Temperature -55°C to +70°C
Refill Capability Refillable by Refill Kit
System Weight 18 ±0.5 kg / 30 ±0.5 kg
MTBF 250,000 Hours
Activation Pyrotechnic Activation
Military Standards MIL-STD-810H / 461G / 1275E
Respiration Support Substance Sodium Bicarbonate
Certification Standards UL / CE / GOST-R
Fire Bulgaria / Product Support

Need More Information About This System?

Contact our team for product specifications, system configuration and application-specific fire suppression requirements.

Request Information